## Transformer action

Alternating primary current creates changing magnetic flux. This induces a secondary e.m.f. through the shared core.

![A step-up transformer. An a.c. supply connects to a primary coil with few turns. A secondary coil with more turns connects to a lamp. Both coils sit on one laminated iron core.](https://spmtuition.com/diagrams/transformer.svg)

*Tap a number to read what each part does.*

- **a.c. supply:** Supplies a changing current. A steady d.c. supply does not keep transformer action.
- **Primary coil:** The alternating current in this coil makes a changing magnetic flux in the core.
- **Laminated soft iron core:** Links the flux from the primary coil to the secondary coil. The laminations reduce eddy currents.
- **Secondary coil:** The changing flux induces an e.m.f. here. This coil has more turns, so Vₛ > Vₚ.
- **Output:** The lamp receives the secondary voltage, Vₛ.

| Quantity or condition | Relationship or meaning |
| --- | --- |
| Turns ratio | Vₛ/Vₚ = Nₛ/Nₚ |
| Ideal power balance | VₚIₚ = VₛIₛ |
| Step-up | More secondary turns; higher secondary voltage |
| Step-down | Fewer secondary turns; lower secondary voltage |
| Efficiency | Output power/input power × 100% |

> **Exam tip:** A steady d.c. supply does not sustain transformer action.

### Practice questions: Transformer action

1. Why must a simple transformer use alternating current?
   A. It produces changing magnetic flux
   B. It has no resistance
   C. It has no voltage
   D. It prevents every loss
   **Answer:** A. It produces changing magnetic flux. Changing flux induces the secondary e.m.f.

2. Which turns ratio gives a step-up transformer?
   A. Nₛ < Nₚ
   B. Nₛ > Nₚ
   C. Nₛ = 0
   D. Any ratio always steps up
   **Answer:** B. Nₛ > Nₚ. More secondary turns gives higher output voltage.

3. An ideal transformer doubles voltage. What happens to current?
   A. It halves
   B. It doubles
   C. It quadruples
   D. It stays constant
   **Answer:** A. It halves. Input and output powers are equal ideally.

## Losses and transmission

*Graph of Ploss = I²R: For fixed line resistance R, compare power loss as current changes.* (interactive on the web page)

| Quantity or condition | Relationship or meaning |
| --- | --- |
| Copper heating | Use low-resistance winding wire. |
| Eddy currents | Use an insulated laminated core. |
| Magnetic hysteresis | Use a soft magnetic core. |
| Flux leakage | Link both coils closely through the core. |
| Transmission loss | Ploss = I²R; high voltage lowers current for the same power. |

**Worked example:** An ideal transformer changes 240 V to 12 V. The primary has 1000 turns. Find secondary turns.

1. Nₛ = NₚVₛ/Vₚ
2. Nₛ = 1000 × 12/240
3. Nₛ = 50

**Answer:** 50 turns

### Practice questions: Losses and transmission

1. Why laminate the core?
   A. To increase eddy currents
   B. To stop all magnetic flux
   C. To reduce eddy-current losses
   D. To increase wire resistance
   **Answer:** C. To reduce eddy-current losses. Insulated laminations restrict circulating currents.

2. Why transmit a fixed power at high voltage?
   A. To increase current
   B. To eliminate all resistance
   C. To create extra energy
   D. To reduce current and I²R loss
   **Answer:** D. To reduce current and I²R loss. P = VI gives smaller I when V increases.

---